Shear is a type of stress in which an applied force causes a structure to 'slide' in two or more directions. Shear can cause a structural member to split vertically or diagonally. For example, a cantilever beam built into a wall may shear at the point of support due either to its own weight or the applied forces, or both.
Shear strength is the ability of a material or component to resist shear forces without failing or, put another way, the maximum shear force that can be accommodated before failing.
Shear strength is analogous to ultimate tensile strength (UTS). The difference is that in shear the strain is parallel to the face (or cross-section) of the element in question whereas tensile strain is at right angles.
In structures, knowing the shear strength of materials is critical to be able to design or specify structural components (e.g beams, plates, bolts etc) economically whilst still withstanding shear forces.
In timber, shear strength tends to be affected by the direction of loading in relation to the grain. The shear strength tends to be around 10-15% of its tensile strength (in the direction of the grain). But shear strength will be reduced by the presence of knots, cracks and faults.
Adhesives tend to have high shear strengths. This can be measured by bonding two strips together then pulling them apart under a constant load. Typically, an epoxy resin adhesive can have shear strengths in the region of 26MPa, however, this is an idealised test and in use the shear strength of an adhesive can depend on many variables including surface preparation, conditions and so on.
Bolts can have a critical function in structures, for example, if they are used to connect a steel frame together or fix steel beams to a concrete core. In such instances, bolts may be required to withstand significant shear forces.
Typical shear strengths include:
In soil mechanics, the shear strength of soil is the shear force which can be sustained by the soil. This is dependent on numerous variables such as the friction between particles and the degree of interlock between them, whether they are cemented together or bonded at contact surfaces and so on.
Determining the shear strength of a cohesionless soil can be achieved by using either a direct shear test or a box shear test. Using the direct shear method allows the cohesion and angle of internal friction of soil to be established, which can be useful in the engineering design of elements such as foundations and retaining walls.
The direct shear test can be applied to the following soil conditions:
- Unconsolidated-undrained.
- Consolidated-undrained.
- Consolidated-drained.
See also: Shear.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Heat pumps, vehicle chargers and heating appliances must be sold with smart functionality.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
New-style degrees set for reformed ARB accreditation
Following the ARB Tomorrow's Architects competency outcomes for Architects.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.
Preserving, waterproofing and decorating buildings.
Many resources for visitors aswell as new features for members.
Using technology to empower communities
The Community data platform; capturing the DNA of a place and fostering participation, for better design.
Heat pump and wind turbine sound calculations for PDRs
MCS publish updated sound calculation standards for permitted development installations.
Homes England creates largest housing-led site in the North
Successful, 34 hectare land acquisition with the residential allocation now completed.
Scottish apprenticeship training proposals
General support although better accountability and transparency is sought.
The history of building regulations
A story of belated action in response to crisis.
Moisture, fire safety and emerging trends in living walls
How wet is your wall?
Current policy explained and newly published consultation by the UK and Welsh Governments.
British architecture 1919–39. Book review.
Conservation of listed prefabs in Moseley.
Energy industry calls for urgent reform.